It contains span tables covering various primary and secondary beam spans with common design floor loadings.
Steel roof batten span tables.
Each product has different requirements for example batten spacing for 0 42bmt corrugated metal roofing needs to be no more than 1100 mm apart but batten spacing for 0 48bmt metal roofing can be up to 1600 mm apart.
Note that spanman automatically calculates the weight of roof battens and adds it to the roof weight.
Ceiling joist span use this table to determine the maximum lengths of ceiling joists based on species of lumber joist spacing and joist size.
Your choice of batten size here will be determined by the weight and span of your metal roof panels.
If additional fall protection is required on steel sheet roofs stratco ceiling battens may be fixed intermittently between stratco roofing battens giving a batten spacing no greater than 600mm.
Based on the foot traffic requirements of as3623 the maximum span for stramit 0 48 roof batten is 900mm and stramit 0 55 roof batten is 1200mm.
Rafter spans can be extended slightly beyond what the rafter tables suggest when there is a cantelever extending beyond the supporting wall.
Steeline metal roof battens are a versatile and easy to use batten compatible with all roof.
Design of single span rafters in roofs in houses office buidlings schools and other structures.
Span tables have been produced in combination with calculations derived from as nzs 4600 and using software developed by the centre for advanced structural engineering at the university of sydney.
For details of weights refer to about technical.
As 1397 2011 steel sheet strip g550 mpa steel roof ceiling battens.
Stramit roof batten 0 48 0 48 mm g550 0 60 kg m stramit roof batten 0 55 0 55 mm g550 0 77 kg m stramit cyclonic roof batten 0 75 mm g550 0 98 kg m stramit ceiling batten 0 42 mm g550 0 37 kg m stramit wa ceiling batten 0 42 mm g550 0 34 kg m.
It is intended that these tables will be used by engineers to assist in the preliminary design.
Refer to stratco for applications in higher wind conditions.
As 1170 and then determined the span required from the table below.
Material specification material truecore roof batten hi tensile steel section is produced from hi tensile grade g550 az150 550.
Embossed top flange provides slip resistance for roof fixers.
Appendix c span tables c 1 introduction this appendix has been taken from the onesteelpublication design note no.
Loads are calculated in accordance with table 3 1 of as nzs 1170 1 2002.
This assumes a maximum batten spacing of 300mm and a maximum tile weight of 0 67 kpa.